Publications

Export 103 results:
Sort by: Author Title Type [ Year  (Desc)]
2021
Mukhtar, A., M. AbdelGhany, A. Hasanin, W. Hamimy, A. Abougabal, H. Nasser, A. Elsayed, and E. Ayman, "The Novel Use of Point-of-Care Ultrasound to Predict Resting Energy Expenditure in Critically Ill Patients.", Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine, vol. 40, issue 8, pp. 1581-1589, 2021. Abstract

OBJECTIVES: Accurate estimation of a critically ill patient's caloric requirements is essential for a proper nutritional plan. This study aimed to evaluate the use of point-of-care ultrasound (US) to predict the resting energy expenditure (REE) in critically ill patients.

METHODS: In 69 critically ill patients, we measured the REE using indirect calorimetry (REE_IC), muscle layer thicknesses (MLTs), and cardiac output (CO). Muscle thickness was measured at the biceps and the quadriceps muscles. Patients were randomly split into a model development group (n = 46) and a cross-validation group (n = 23). In the model development group, a multiple regression analysis was applied to generate REE using US (REE_US) values. In the cross-validation group, REE was calculated by the REE_US and the resting energy expenditure using the Harris-Benedict equation (REE_HB), and both were compared to the REE_IC.

RESULTS: In the model development group, the REE_US was predicted by the following formula: predicted REE_US (kcal/d) = 206 + 173.5 × CO (L/min) + 137 × MLT (cm) - 230 × (women = 1; men = 0) (R  = 0.8; P < .0001). In the cross-validated group, the REE_IC and REE_US values were comparable (mean difference, -66 [-3.3%] kcal/d; P = .14). However, the difference between the mean REE_IC and the mean REE_HB was 455.8 (26%) kcal/d (P < .001). According to a Bland-Altman analysis, the REE_US agreed well with the REE_IC, whereas the REE_HB did not.

CONCLUSIONS: Resting energy expenditure could be estimated from US measurements of MLTs and CO. Our point-of-care US model explains 80% of the change in the REE in critically ill patients.

ahmed lotfy, A. Hasanin, M. Rashad, M. Mostafa, D. Saad, M. Mahmoud, W. Hamimy, and A. Z. Fouad, "Peripheral perfusion index as a predictor of failed weaning from mechanical ventilation.", Journal of clinical monitoring and computing, vol. 35, issue 2, pp. 405-412, 2021. Abstract

We hypothesized that impairment of peripheral perfusion index (PPI) during spontaneous breathing trial (SBT) might be predictive of weaning failure. We included 44 consecutive, adult, patients, who were scheduled for weaning after at least 48 h of invasive mechanical ventilation in this prospective observational study. Weaning failure was defined as failed SBT or reintubation within 48 h of extubation. PPI readings were obtained before initiation of the SBT, and every 5 min till the end of the SBT. PPI ratio was calculated at every time point as: PPI value/ baseline PPI. The primary outcome was the accuracy of PPI ratio at the end of the SBT in detecting failed weaning. Forty-three patients were available for the final analysis. Eighteen patients (42%) were considered failed weaning. PPI ratio was higher in patients with successful weaning compared to patients with failed weaning during the last 15 min of the SBT. PPI ratio at the end of SBT was higher in patients with successful weaning compared to patients with failed weaning. PPI ratio at the end of SBT had good predictive ability for weaning failure {area under receiver operating characteristic curve (95% confidence interval): 0.833(0.688-0.929), cutoff value ≤ 1.41}. The change in PPI during SBT is an independent predictor for re-intubation. PPI could be a useful tool for monitoring the patient response to SBT. Patients with successful weaning showed higher augmentation of PPI during the SBT compared to re-intubated patients. Failure of augmenting the PPI by 41% at the end of SBT could predict re-intubation with negative predictive value of 95%. Clinical trial identifier: NCT03974568. https://clinicaltrials.gov/ct2/show/NCT03974568?term=ahmed+hasanin&amp;draw=3&amp;rank=17.

Elshal, M. M., A. M. Hasanin, M. Mostafa, and R. M. Gamal, "Plethysmographic Peripheral Perfusion Index: Could It Be a New Vital Sign?", Frontiers in medicine, vol. 8, pp. 651909, 2021. Abstract

The plethysmographic peripheral perfusion index (PPI) is a very useful parameter with various emerging utilities in medical practice. The PPI represents the ratio between pulsatile and non-pulsatile portions in peripheral circulation and is mainly affected by two main determinants: cardiac output and balance between sympathetic and parasympathetic nervous systems. The PPI decreases in cases of sympathetic predominance and/or low cardiac output states; therefore, it is a useful predictor of patient outcomes in critical care units. The PPI could be a surrogate for cardiac output in tests for fluid responsiveness, as an objective measure of pain especially in un-cooperative patients, and as a predictor of successful weaning from mechanical ventilation. The PPI is simple to measure, easy to interpret, and has continuously displayed variables, making it a convenient parameter for detecting the adequacy of blood flow and sympathetic-parasympathetic balance.

Hasanin, A., and M. Mostafa, "Tocilizumab in patients with COVID-19: which patient, time, and dose?", Journal of anesthesia, 2021. Abstract

Tocilizumab (TCZ) is a recombinant anti-interleukin-6 monoclonal antibody which showed uprising evidence as an anti-inflammatory agent which modulates the cytokine storm in patients with COVID-19. However, proper use of the drug requires selection of the appropriate patient and timing. The two main factors which might improve patient selection are the degree of respiratory failure and systemic inflammation. TCZ can decrease the mortality and progression to invasive mechanical ventilation in patients with severe COVID-19 who are not yet invasively ventilated. However, its use in invasively ventilated patients did not yet gain the same level of evidence especially when administered after > 1 day from mechanical ventilation. Being an anti-inflammatory and immunomodulatory drug, TCZ was mostly used in patients with COVID-19 who have clear signs of cytokine storm. However, the drug still showed positive response in some studies which did not strictly select patients with elevated markers of systemic inflammation. Thus, it is warranted to investigate and/or re-analyze the role of the drug in patients with severe COVID-19 and with no signs of systemic inflammation. TCZ is used in a dose of 8 mg/kg which can be repeated if there was no clinical improvement. However, there are no clear criteria for judgment of the success of the first dose. Being a drug with a major effect on gross outcomes in a serious pandemic with millions of mortalities, TCZ should be meticulously investigated to reach definitive indications and number of doses to avoid drug overuse, shortage, and side effects.

Nassar, H., A. Hasanin, M. Sewilam, H. Ahmed, M. Abo-elsoud, O. Taalab, A. Rady, and H. A. Zoheir, "Transmuscular Quadratus Lumborum Block versus Suprainguinal Fascia Iliaca Block for Hip Arthroplasty: A Randomized, Controlled Pilot Study.", Local and regional anesthesia, vol. 14, pp. 67-74, 2021. Abstract

Background: This study aimed to investigate the analgesic efficacy and motor block profile of single-shot transmuscular quadratus lumborum block (QLB) in comparison with those of suprainguinal fascia iliaca block (FIB) in patients undergoing hip arthroplasty.

Methods: This randomized, double-blinded, controlled trial included adult patients undergoing hip arthroplasty under spinal anesthesia. Patients were allocated to one of two groups according to the regional block received: FIB group (n=19) or QLB group (n=17). Both study groups were compared with regard to the duration of analgesia (primary outcome), block performance time, pain during positioning for spinal anesthesia, total morphine consumption in the first postoperative 24-h period, quadriceps muscle power, and static and dynamic visual analog scale.

Results: Thirty-six patients were included in the final analysis. Both study groups had comparable durations of analgesia. Postoperative visual analog scale (static and dynamic) values were comparable between the two groups in most readings. The block performance time was shorter in the FIB group. The number of patients with pain during positioning for the subarachnoid block was lower in the QLB group. The total morphine requirement during the first 24 h was marginally lower in the FIB group, whereas the quadriceps motor grade was higher in the FIB group than in the QLB group at 4 h and 6 h after surgery.

Conclusion: Both single-shot blocks, namely the suprainguinal FIB and transmuscular QLB, provide effective postoperative analgesia after hip arthroplasty. FIB showed slightly lower 24-h morphine consumption, while QLB showed better quadriceps motor power.

Clinical Trial Registration: The study was registered at clinical trials registry system before enrollment of the first participant (NCT04005326; initial release date, 2 July 2019; https://clinicaltrials.gov/ct2/show/NCT04005326).

Abdelhakeem, A. K., A. Amin, A. Hasanin, A. Mukhtar, akram eladawy, and S. Kassem, "Validity of Pulse Oximetry-derived Peripheral Perfusion Index in Pain Assessment in Critically Ill Intubated Patients.", The Clinical journal of pain, vol. 37, issue 12, pp. 904-907, 2021. Abstract

OBJECTIVES: Evaluation of pain in critically ill intubated patients is difficult and subjective. This study aimed to evaluate the accuracy of oximetry-derived peripheral perfusion index (PPI) in pain assessment in critically ill intubated patients using the behavioral pain scale (BPS) as a reference.

MATERIALS AND METHODS: This prospective observational study included 35 adult mechanically ventilated surgical patients during their first 2 postoperative days in the intensive care unit. Values of PPI, BPS, Richmond Agitation Sedation Scale (RASS), heart rate, and blood pressure were obtained before and after a standard painful stimulus (changing the patient position) and the ratio between the second and the first reading was calculated to determine the change (Δ) in all variables. The outcomes were the correlation between ΔBPS and ΔPPI as well as other hemodynamic parameters. The ability of the PPI to detect pain (defined as BPS ≥6) was analyzed using the area under receiver operating characteristic curve.

RESULTS: Paired readings were obtained from 35 patients. After the standard painful stimulus, the PPI decreased while the BPS and the Richmond agitation sedation scale increased. The Spearman correlation coefficient (95% confidence interval) between Δ PPI and Δ BPS was 0.41 (0.09-0.65). PPI values showed poor accuracy in detecting pain with area under receiver operating characteristic curve (95% confidence interval): 0.65 (0.53-0.76), with best cutoff value of ≤2.7.

CONCLUSION: The PPI decreased after application of a standard painful stimulus in critically ill intubated patients. ∆PPI showed a low correlation with ∆BPS, and a PPI of ≤2.7 showed a low ability to detect BPS ≥6. Therefore, PPI should not be used for pain evaluation in critically ill intubated surgical patients.

2020
Elhamid, B. A., mohamed emam, M. Mostafa, A. Hasanin, W. Awada, A. Rady, and H. Omar, "The ability of perfusion index to detect segmental ulnar nerve sparing after supraclavicular nerve block.", Journal of clinical monitoring and computing, vol. 34, issue 6, pp. 1185-1191, 2020. Abstract

Supraclavicular nerve block (SCB) is a commonly used regional block for upper extremity surgery. The most common form of failure of SCB is ulnar segmental sparing. We aimed to evaluate the accuracy of perfusion index (PI) in early detection of segmental sparing of the ulnar component of SCB. A prospective observational study included adult patients scheduled for surgery under ultrasound-guided SCB. PI was simultaneously measured at the index finger and little finger. PI was recorded every minute for the first 10 min after SCB. PI ratio was calculated at every measurement point as PI/baseline PI. The area under the receiver operating characteristic (AUROC) curve was calculated for the ability of PI ratio to detect segmental ulnar sparing with comparison of little finger readings to the index finger readings. Forty-nine patients were available for the final analysis. Nine patients (18%) had segmental ulnar sparing. PI ratio at the little finger showed excellent predictive ability for ulnar sparing starting from the fifth minute (AUROC 0.92 [0.8-0.98], cutoff value ≤ 1.71) and reached the highest value at the seventh minute (AUROC 0.96 [0.86-1], cutoff value ≤ 1.35), whereas PI ratio at the index finger showed poor predictive ability. When using the PI for evaluation of successful SCB, segmental ulnar sparing could be accurately detected when the PI was measured at the little finger and not at the index finger. An increase of 71% in PI at the little finger 5 min after SCB could accurately rule out ulnar sparing.Clinical trial identifier NCT03880201. Clinical trial registration https://clinicaltrials.gov/ct2/show/NCT03880201?term=NCT03880201&amp;draw=2&amp;rank=1 .

Mostafa, M. M. A., A. M. Hasanin, F. Alhamade, B. A. Elhamid, A. G. Safina, S. M. Kasem, Osama Hosny, M. Mahmoud, E. fouad, A. Rady, et al., "Accuracy and trending of non-invasive oscillometric blood pressure monitoring at the wrist in obese patients.", Anaesthesia, critical care & pain medicine, vol. 39, issue 2, pp. 221-227, 2020. Abstract

BACKGROUND: In obese patients, non-invasive blood pressure monitoring in the arm is difficult due to the arm size and morphology. We compared the non-invasive oscillometric wrist blood pressure measurement with the arm and forearm in obese patients monitored with invasive radial blood pressure (reference standard).

METHODS: This prospective observational study included adult obese patients scheduled for bariatric surgery. Non-invasive blood pressure was measured at the arm, upper forearm and wrist of one upper extremity, while invasive blood pressure was simultaneously measured through a radial arterial catheter in the contralateral upper extremity. The accuracy of non-invasive blood pressure reading at each site was evaluated for absolute and trending values using the Bland-Altman analysis and Spearman's correlation coefficient.

RESULTS: In 40 patients, 262, 259, and 263 pairs of non-invasive blood pressure readings were obtained from the arm, forearm, and wrist sites, respectively. As primary outcome, the correlation coefficient for systolic blood pressure was higher for the wrist (0.92, 95% confidence interval (CI) [0.9-0.94]) than for the arm (0.74, 95% CI [0.68-0.79]) and the forearm (0.71, 95% CI [0.64-0.76]) (P<0.05). The non-invasive systolic wrist blood pressure showed the least mean bias and the narrowest limits of agreement (-0.3±7.6mmHg) when compared with forearm (4.3±16) and arm measurements (14.2±13.6) (P<0.05). For trending values, the correlation coefficient was the highest at the wrist.

CONCLUSION: In obese patients undergoing bariatric surgery, non-invasive blood pressure measured at the wrist showed the highest accuracy in comparison with the arm and forearm.

Mostafa, M., M. Saeed, A. Hasanin, S. Badawy, and D. KHALED, "Accuracy of thyromental height test for predicting difficult intubation in elderly.", Journal of anesthesia, vol. 34, issue 2, pp. 217-223, 2020. Abstract

BACKGROUND: Studies of the accuracy of different airway tests are lacking in elderly. We evaluated and compared the accuracy of thyromental height in predicting difficult intubation in relation to the other traditional airway tests in elderly.

METHODS: We included 120 patients aged ≥ 65 years scheduled for general anesthesia with tracheal intubation. Thyromental height, modified Mallampati test, thyromental distance and sternomental distance were evaluated. Cormack-Lehane grade > 2 was considered difficult laryngoscopy. Difficult tracheal intubation was considered if successful intubation required more than 2 attempts. The accuracy of different tests in predicting difficult intubation and difficult laryngoscopy were evaluated through area under receiver operating characteristic (AUROC) curves. Univariate and multivariate analyses were conducted to identify risk factors for difficult intubation and difficult laryngoscopy.

RESULTS: Our cohort had a mean age of 71(7) years. We encountered difficult laryngoscopy in 15/120 (12%) patients, difficult intubation in 20/120 (17%) patients, and failed laryngoscopy requiring alternative methods for securing the airway in 3/120 (3%) patients. For predicting difficult intubation, thyromental height and modified Mallampati test showed the highest accuracy AUROC (95% confidence interval): 0.9 (0.83-0.95), cut-off value ≤ 5.9 cm, and AUROC (95% confidence interval): 0.89 (0.82-0.94), cut-off value > 2, respectively. Low thyromental height and high modified Mallampati test were the only independent risk factors for difficult laryngoscopy and difficult intubation.

CONCLUSION: In elderly scheduled for elective procedure, both thyromental height and modified Mallampati tests showed good accuracy in predicting difficult intubation and difficult laryngoscopy, whilst thyromental distance and sternomental distance were poor predictors.

Hassabelnaby, Y. S., A. M. Hasanin, N. Adly, M. M. A. Mostafa, S. Refaat, E. fouad, M. Elsonbaty, H. A. Hussein, M. Mahmoud, Y. M. Abdelwahab, et al., "Comparison of two Norepinephrine rescue bolus for Management of Post-spinal Hypotension during Cesarean Delivery: a randomized controlled trial.", BMC anesthesiology, vol. 20, issue 1, pp. 84, 2020. Abstract

BACKGROUND: Data on the best norepinephrine bolus dose for management of hypotension are limited. The aim of this study was to compare the efficacy and safety of two norepinephrine bolus doses in the rescue management of maternal hypotension during cesarean delivery.

METHODS: This randomized, controlled trial included mothers scheduled for cesarean delivery with spinal anesthesia with a prophylactic norepinephrine infusion. Following spinal anaesthesia administration, a participant was considered hypotensive if systolic blood pressure was ≤80% compared to the baseline reading. Participants were allocated to receive either 6 mcg or 10 mcg norepinephrine bolus for the management of hypotensive episodes. The hemodynamic response after administration of norepinephrine bolus was recorded. The episode was considered successfully managed if systolic blood pressure returned to within 80% from the baseline reading within 2 min after norepinephrine bolus administration, and did not drop again within 6 min after the norepinephrine bolus. The primary outcome was the incidence of successful management of the first hypotensive episode. Other outcomes included systolic blood pressure, heart rate, incidence of maternal bradycardia, and reactive hypertension.

RESULTS: One hundred and ten mothers developed hypotensive episodes and received norepinephrine boluses for management. The number of successfully managed first hypotensive episodes was 50/57 (88%) in the 6 mcg-treated episodes and 45/53 (85%) in the 10 mcg-treated episodes (p = 0.78). Systolic blood pressure was comparable after administration of either bolus dose. Heart rate was lower after administration of 10 mcg bolus compared to 6 mcg bolus, without significant bradycardia requiring atropine administration. The incidence of reactive hypertension was comparable between both groups.

CONCLUSION: In mothers undergoing elective cesarean delivery under prophylactic norepinephrine infusion at 0.05 mcg/kg/min, there was no advantage to the use of 10 mcg norepinephrine bolus over 6 mcg norepinephrine bolus for the rescue management of first hypotensive episode. Neither of the 2 bolus doses reached a 100% success rate. The incidences of bradycardia and reactive hypertension were comparable between both norepinephrine doses.

TRIAL REGISTRATION: At clinicaltrial.gov registry system on January 4, 2019 Clinical trial identifier: NCT03792906.

Zayed, M., H. Nassar, A. Hasanin, A. H. Saleh, P. Hassan, D. Saad, S. A. H. A. R. MAHMOUD, G. A. Bakr, E. fouad, N. Saleh, et al., "Effects of nitroglycerin versus labetalol on peripheral perfusion during deliberate hypotension for sinus endoscopic surgery: a randomized, controlled, double-blinded trial.", BMC anesthesiology, vol. 20, issue 1, pp. 85, 2020. Abstract

BACKGROUND: Deliberate hypotension is used to provide a bloodless field during functional endoscopic sinus surgery; however, the impact of controlled hypotension during anesthesia on peripheral tissue perfusion has not been extensively evaluated. The aim of this study was to compare the impact of nitroglycerin- versus labetalol-induced hypotension on peripheral perfusion.

METHODS: The present randomized, double-blinded, controlled trial included adult patients undergoing endoscopic sinus surgery. Patients were allocated to one of two groups according to the drug received for induction of deliberate hypotension: nitroglycerin (n = 20) or labetalol (n = 20). Mean arterial pressure was maintained at 55-65 mmHg in both groups. Both study groups were compared according to pulse oximeter-derived peripheral perfusion index (primary outcome), serum lactate level, mean arterial pressure, heart rate, surgical field score, and intraoperative blood loss.

RESULTS: Forty patients were included in the final analysis. The nitroglycerin group exhibited a higher peripheral perfusion index at nearly all records (p < 0.0001) and lower postoperative serum lactate levels (1.3 ± 0.2 mmol/L vs. 1.7 ± 0.4 mmol/L; p = 0.001) than the labetalol group. The peripheral perfusion index was higher in the nitroglycerin group than at baseline at most intraoperative readings. The median surgical field score was modestly lower in the labetalol group than in the nitroglycerin group in the first 20 min (2 [interquartile range (IQR) 2-2.5] versus 1.5 [IQR 1-2]; p = 0.001). Both groups demonstrated comparable and acceptable surgical field scores in all subsequent readings.

CONCLUSION: Nitroglycerin-induced deliberate hypotension was accompanied by higher peripheral perfusion index and lower serum lactate levels than labetalol-induced deliberate hypotension during sinus endoscopic surgery.

TRIAL REGISTRATION: The study was registered at clinicaltrials registry system with trial number: NCT03809065. Registered at 19 January 2019. This study adheres to CONSORT guidelines.

Hasanin, A., and M. Mostafa, "Evaluation of fluid responsiveness during COVID-19 pandemic: what are the remaining choices?", Journal of anesthesia, vol. 34, pp. 758-764, 2020.
Kamel, M. M., A. Hasanin, B. Nawar, M. Mostafa, V. F. Jacob, H. Elhadi, W. Alsadek, and S. A. Elmetwally, "Evaluation of noninvasive hemoglobin monitoring in children with congenital heart diseases.", Paediatric anaesthesia, vol. 30, issue 5, pp. 571-576, 2020. Abstract

BACKGROUND: Noninvasive measurement of blood hemoglobin could save time and decrease the risk of anemia and infection. The accuracy of CO-oximetry-derived noninvasive hemoglobin (Sp-Hb) had been evaluated in pediatric population; however, its accuracy in children with congenital heart disease has not been studied till date. We evaluated the accuracy of Sp-Hb in relation to laboratory-measured hemoglobin (Lab-Hb) in children with congenital heart disease.

METHODS: This prospective observational study included children with congenital heart disease undergoing procedural intervention. Sp-Hb measurements were obtained using Radical-7 Masimo pulse CO-oximeter and were compared against simultaneous Lab-Hb measurements obtained from the arterial line. Children were divided in cyanotic and acyanotic, and separate analysis was performed for each group. The values of both measurements were analyzed using Spearman's correlation coefficient and Bland-Altman analysis. Correlation was performed between Sp-Hb and Lab-Hb bias and each of arterial oxygen saturation and perfusion index.

RESULTS: One-hundred and eleven pairs of readings were obtained from 65 children. The median (quartiles) age and weight of the children were 1 (1.2-4) years and 11 (8-17) kg, respectively. There was moderate correlation between Lab-Hb and Sp-Hb with a correlation coefficient (95% confidence interval [CI]) of 0.75 (0.63-0.83) in acyanotic children and 0.62 (0.37-0.79) in cyanotic children. The mean bias (95% limits of agreements) was -0.4 g/dL (-2.4 to 1.6 g/dL) and 1 g/dL (-2.7 to 4.6 g/dL) in acyanotic and cyanotic children, respectively. The mean bias between Sp-Hb and Lab-Hb showed a weak negative correlation with oxygen saturation (r [95% CI]): (-0.36 [-0.51--0.18]), and a weak positive correlation with the perfusion index (r [95% CI]): (0.19 [0.01-0.37]).

CONCLUSION: The large bias and the wide limits of agreement between Sp-Hb and Lab-Hb denote that Masimo-derived Sp-Hb is not accurate in children with congenital heart disease especially in the cyanotic group; the error in Sp-Hb increases when oxygen saturation decreases.

Hasanin, A., H. Tarek, M. M. A. Mostafa, A. Arafa, A. G. Safina, M. H. Elsherbiny, Osama Hosny, A. A. Gado, T. Almenesey, G. A. Hamden, et al., "Modified-ramped position: a new position for intubation of obese females: a randomized controlled pilot study.", BMC anesthesiology, vol. 20, issue 1, pp. 151, 2020. Abstract

BACKGROUND: Endotracheal intubation requires optimum position of the head and neck. In obese females, the usual ramped position might not provide adequate intubating conditions. We hypothesized that a new position, termed modified-ramped position, during induction of anesthesia would facilitate endotracheal intubation through bringing the breasts away from the laryngoscope and would also improve the laryngeal visualization.

METHODS: Sixty obese female patients scheduled for general anesthesia were randomly assigned into either ramped or modified-ramped position during induction of anesthesia. In the ramped position (n = 30), the patient head and shoulders were elevated to achieve alignment of the sternal notch and the external auditory meatus; while in the modified-ramped position (n = 30), the patient shoulders were elevated using a special pillow, and the head was extended to the most possible range. Our primary outcome was the incidence of failed laryngoscopic insertion in the oral cavity (the need for patient repositioning). Other outcomes included time till vocal cord visualization, time till successful endotracheal intubation, difficulty of the mask ventilation, and Cormack-Lehane grade for laryngeal view.

RESULTS: Fourteen patients (47%) in ramped group required repositioning to facilitate introduction of the laryngoscope in the oral cavity in comparison to one patient (3%) in the modified-ramped position (p < 0.001). Modified-ramped position showed lower incidence of difficult mask ventilation, shorter time for glottic visualization, and shorter time for endotracheal tube insertion compared to the ramped position. The Cormack-Lehane grade was better in the modified-ramped position.

CONCLUSION: Modified-ramped position provided better intubating conditions, improved the laryngeal view, and eliminated the need for repositioning of obese female patients during insertion of the laryngoscope compared to ramped position.

CLINICAL TRIAL REGISTRATION: Identifier: NCT03640442. Date: August 2018.

Mukhtar, A., ahmed lotfy, A. Hasanin, I. El-Hefnawy, and A. El-adawy, "Outcome of non-invasive ventilation in COVID-19 critically ill patients: A Retrospective observational Study", Anaesthesia Critical care & Pain Medicine, vol. 39, pp. 579-580, 2020.
Hasanin, A., and Y. Hassabelnaby, "Perioperative non-invasive haemodynamic optimisation: Is photoplethysmography really useless?", Anaesthesia Critical care & Pain Medicine, vol. 39, pp. 625, 2020.
Hasanin, A., and M. Mostafa, "A reply to a letter", Journal of anesthesia, vol. 34, pp. 631, 2020.
Elmetwally, S. A., A. Hasanin, L. Sobh, M. Gohary, K. Sarhan, and D. Ghazy, "Semi-sitting position enhances gastric emptying of clear fluids in children: A randomized controlled trial", Egyptian Journal of Anaesthesia, vol. 36, pp. 170-175, 2020.
Fathy, S., A. Hasanin, M. Raafat, M. Mostafa, A. fetouh, M. E. Sayed, E. M. Badr, H. M. Kamal, and A. Z. Fouad, "Thoracic fluid content: a novel parameter for predicting failed weaning from mechanical ventilation", Journal of intensive care, vol. 8, pp. 20, 2020.
Hasanin, A., A. Aboelela, M. Mostafa, R. M. Mansour, and A. Kareem, "The Use of Topical Nitroglycerin to Facilitate Radial Arterial Catheter Insertion in Children: A Randomized Controlled Trial.", Journal of cardiothoracic and vascular anesthesia, vol. 34, issue 12, pp. 3354-3360, 2020. Abstract

OBJECTIVES: To determine whether the use of topical nitroglycerin patch increases radial artery diameter and facilitate cannulation in children.

DESIGN: Randomized controlled trial.

SETTING: Cairo University Hospital.

PARTICIPANTS: Children aged 2 to 8 years old scheduled for cardiac surgery.

INTERVENTION: In the nitroglycerin group (n = 20), a gauze-covered, half-sized nitroglycerin patch (5 mg) was applied at the site of radial pulsation 1 hour before induction of anesthesia. In the control group (n = 20), a gauze pad was applied to the bare skin at the site of radial pulsation with no intervention.

MEASUREMENTS AND MAIN RESULTS: The primary outcome was the diameter of the radial artery in both limbs using ultrasonography. Other outcomes included the degree of arterial palpability, number of arterial punctures, and incidence of successful first puncture cannulation. The radial artery diameter increased after 30 minutes and 60 minutes compared with the baseline value in the nitroglycerin group in both limbs, whereas no change was reported in the radial artery diameter in the control group. The nitroglycerin group showed a greater incidence of successful first cannulation trial, a fewer number of trials, and a shorter cannulation time compared with the control group. There were no significant hypotensive episodes in any patient.

CONCLUSION: Local application of a half-sized, 5 mg nitroglycerin patch for 60 minutes in children increased the radial artery diameter bilaterally, increased the rate of first trial success, and decreased the time needed for arterial cannulation without significant hypotensive episodes.

2019
Eltrabili, H. H., A. Hasanin, M. S. Soliman, A. M. Lotfy, W. I. Hamimy, and A. H. M. E. D. M. MUKHTAR, "Evaluation of Diaphragmatic Ultrasound Indices as Predictors of Successful Liberation From Mechanical Ventilation in Subjects With Abdominal Sepsis", Respiratory Care, vol. 64, issue 5, pp. 564-569, 2019.
Sabry, R., A. Hasanin, S. Refaat, S. A. E. Raouf, A. S. Abdallah, and N. Helmy, "Evaluation of Gastric Residual Volume in Fasting Diabetic Patients Using Gastric Ultrasound", Acta Anaesthesiologica Scandinavica, vol. 63, issue 5, pp. 615-619, 2019.
hanan mostafa, M. Shaban, A. Hasanin, H. Mohamed, S. Fathy, H. M. Abdelreheem, ahmed lotfy, and A. Abougabal, "Evaluation of peripheral perfusion index and heart rate variability as early predictors for intradialytic hypotension in critically ill patients.", BMC Anesthesiology, vol. 19, issue 1, pp. 242, 2019.
Hasanin, A., K. H. Mourad, I. Farouk, S. Refaat, A. Nabih, S. A. E. Raouf, and H. Ezzat, "The Impact of Goal-Directed Fluid Therapy in Prolonged Major Abdominal Surgery on Extravascular Lung Water and Oxygenation: A Randomized Controlled Trial.", Open Access Macedonian Journal of Medical Sciences, vol. 7, issue 8, pp. 1276-1281, 2019.
Mohamed, H., S. M. Abbas, and A. Hasanin, "Management of post laryngectomy tracheobronchial tear with the aid of cardiopulmonary bypass", Journal of Clinical Anesthesia, vol. 55, pp. 128-129, 2019.
Tourism