hanan mostafa, M. Shaban, A. Hasanin, H. Mohamed, S. Fathy, H. M. Abdelreheem, ahmed lotfy, and A. Abougabal, "Evaluation of peripheral perfusion index and heart rate variability as early predictors for intradialytic hypotension in critically ill patients.", BMC Anesthesiology, vol. 19, issue 1, pp. 242, 2019.
Mostafa, M., A. M. Hasanin, O. S. Elsayed, M. M. Mostafa, and K. Sarhan, "Accuracy of oscillometric blood pressure measurement at both arms in the lateral position.", Blood pressure monitoring, vol. 26, issue 5, pp. 364-372, 2021. Abstract

PURPOSE: To evaluate the accuracy of noninvasive blood pressure (NIBP) measurement at the dependent- and nondependent arms in the lateral position, using invasive blood pressure (IBP) as reference.

METHODS: This prospective observational study included 42 adult patients undergoing surgery in the lateral position. Paired readings of IBP and NIBP were obtained at either arm. The accuracy of both arms in detecting mean arterial pressure (MAP) <70 mmHg was evaluated using the area under the receiver operating characteristic curve (AUC). The agreement between the IBP and NIBP was evaluated using the Bland-Altman and error grid analyses.

RESULTS: We analyzed 350 and 347 paired readings at the dependent- and nondependent arms. The AUC for detecting hypotension was comparable in both arms. The negative and positive predictive values (95% confidence interval) were 100% (99-100%) and 24% (14-34%), respectively for the dependent arm at cutoff value MAP ≤86 mmHg; and were 99% (96-100%) and 21% (13-30%), respectively for the nondependent arm at cutoff value MAP ≤75 mmHg. The mean bias for MAP was -6.0 ± 9.1 and 6.3 ± 10.1 mmHg; and for systolic blood pressure was 0.3 ± 11.6 and 13.2 ± 12.6 mmHg, in the dependent- and nondependent arm, respectively. Error grid analysis showed that the proportions of paired MAP readings in risk zone A were 71 and 82% in the dependent- and the nondependent arms, respectively.

CONCLUSION: In the lateral position, the NIBP readings at both arms are not interchangeable with the corresponding IBP readings. However, NIBP measurement at both arms can be used to accurately rule out hypotension.

Mostafa, M., M. Saeed, A. Hasanin, S. Badawy, and D. KHALED, "Accuracy of thyromental height test for predicting difficult intubation in elderly.", Journal of anesthesia, vol. 34, issue 2, pp. 217-223, 2020. Abstract

BACKGROUND: Studies of the accuracy of different airway tests are lacking in elderly. We evaluated and compared the accuracy of thyromental height in predicting difficult intubation in relation to the other traditional airway tests in elderly.

METHODS: We included 120 patients aged ≥ 65 years scheduled for general anesthesia with tracheal intubation. Thyromental height, modified Mallampati test, thyromental distance and sternomental distance were evaluated. Cormack-Lehane grade > 2 was considered difficult laryngoscopy. Difficult tracheal intubation was considered if successful intubation required more than 2 attempts. The accuracy of different tests in predicting difficult intubation and difficult laryngoscopy were evaluated through area under receiver operating characteristic (AUROC) curves. Univariate and multivariate analyses were conducted to identify risk factors for difficult intubation and difficult laryngoscopy.

RESULTS: Our cohort had a mean age of 71(7) years. We encountered difficult laryngoscopy in 15/120 (12%) patients, difficult intubation in 20/120 (17%) patients, and failed laryngoscopy requiring alternative methods for securing the airway in 3/120 (3%) patients. For predicting difficult intubation, thyromental height and modified Mallampati test showed the highest accuracy AUROC (95% confidence interval): 0.9 (0.83-0.95), cut-off value ≤ 5.9 cm, and AUROC (95% confidence interval): 0.89 (0.82-0.94), cut-off value > 2, respectively. Low thyromental height and high modified Mallampati test were the only independent risk factors for difficult laryngoscopy and difficult intubation.

CONCLUSION: In elderly scheduled for elective procedure, both thyromental height and modified Mallampati tests showed good accuracy in predicting difficult intubation and difficult laryngoscopy, whilst thyromental distance and sternomental distance were poor predictors.

Mukhtar, A., I. Rasmy, hossam mohamed, and N. Nabil, "Evaluation of Perfusion Index as a Predictor of Vasopressor Requirement in Patients with Severe Sepsis", shock, vol. 44, issue 6, pp. 554-9, 2015.
Mukhtar, A., A. Hasanin, A. Abelaal, and G. Obayah, "Infection complications and pattern of bacterial resistance in living-donor liver transplantation: A multicenter epidemiologic study in Egypt", transplantation proceedings, vol. 46, issue 5, pp. 1444-7, 2014.
Mukhtar, A., ahmed lotfy, A. Hasanin, I. El-Hefnawy, and A. El-adawy, "Outcome of non-invasive ventilation in COVID-19 critically ill patients: A Retrospective observational Study", Anaesthesia Critical care & Pain Medicine, vol. 39, pp. 579-580, 2020.
Mukhtar, A., M. AbdelGhany, A. Hasanin, W. Hamimy, A. Abougabal, H. Nasser, A. Elsayed, and E. Ayman, "The Novel Use of Point-of-Care Ultrasound to Predict Resting Energy Expenditure in Critically Ill Patients.", Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine, vol. 40, issue 8, pp. 1581-1589, 2021. Abstract

OBJECTIVES: Accurate estimation of a critically ill patient's caloric requirements is essential for a proper nutritional plan. This study aimed to evaluate the use of point-of-care ultrasound (US) to predict the resting energy expenditure (REE) in critically ill patients.

METHODS: In 69 critically ill patients, we measured the REE using indirect calorimetry (REE_IC), muscle layer thicknesses (MLTs), and cardiac output (CO). Muscle thickness was measured at the biceps and the quadriceps muscles. Patients were randomly split into a model development group (n = 46) and a cross-validation group (n = 23). In the model development group, a multiple regression analysis was applied to generate REE using US (REE_US) values. In the cross-validation group, REE was calculated by the REE_US and the resting energy expenditure using the Harris-Benedict equation (REE_HB), and both were compared to the REE_IC.

RESULTS: In the model development group, the REE_US was predicted by the following formula: predicted REE_US (kcal/d) = 206 + 173.5 × CO (L/min) + 137 × MLT (cm) - 230 × (women = 1; men = 0) (R  = 0.8; P < .0001). In the cross-validated group, the REE_IC and REE_US values were comparable (mean difference, -66 [-3.3%] kcal/d; P = .14). However, the difference between the mean REE_IC and the mean REE_HB was 455.8 (26%) kcal/d (P < .001). According to a Bland-Altman analysis, the REE_US agreed well with the REE_IC, whereas the REE_HB did not.

CONCLUSIONS: Resting energy expenditure could be estimated from US measurements of MLTs and CO. Our point-of-care US model explains 80% of the change in the REE in critically ill patients.

Mukhtar, A., A. Rady, A. Hasanin, ahmed lotfy, akram eladawy, A. Hussein, I. El-Hefnawy, M. Hassan, and hanan mostafa, "Admission SpO and ROX index predict outcome in patients with COVID-19.", The American journal of emergency medicine, vol. 50, pp. 106-110, 2021. Abstract

BACKGROUND: This study aimed to evaluate the accuracy of pulse oximetry-derived oxygen saturation (SpO) on room air, determined at hospital admission, as a predictor for the need for mechanical ventilatory support in patients with Coronavirus Disease-2019 (COVID-19).

METHODS: In this retrospective observational study, demographic and clinical details of the patients were obtained during ICU admission. SpO and respiratory rate (RR) on room air were determined within the first 6 h of hospital admission. As all measurements were obtained on room air, we calculated the simplified respiratory rate‑oxygenation (ROX) index by dividing the SpO by the RR. Based on the use of any assistance of mechanical ventilator (invasive or noninvasive), patients were divided into mechanical ventilation (MV) group and oxygen therapy group. The accuracy of the SpO, CT score, and ROX index to predict the need to MV were determined using the Area under receiver operating curve (AUC).

RESULTS: We included 72 critically ill patients who tested COVID-19-positive. SpO on the room air could predict any MV requirement (AUC [95% confidence interval]: 0.9 [0.8-0.96], sensitivity: 70%, specificity 100%, cut-off value ≤78%, P < 0.001). Within the MV group, the use of noninvasive ventilation (NIV) was successful in 37 (74%) patients, whereas 13 patients (26%) required endotracheal intubation. The cut-off ROX value for predicting early NIV failure was ≤1.4, with a sensitivity of 85%, a specificity of 86%, and an AUC of 0.86 (95% confidence interval of 0.73-0.94, P < 0.0001).

CONCLUSIONS: A baseline SpO ≤78% is an excellent predictor of MV requirement with a positive predictive value of 100%. Moreover, the ROX index measured within the first 6 h of hospital admission is a good indicator of early NIV failure.

N
Nassar, H., A. Hasanin, M. Sewilam, H. Ahmed, M. Abo-elsoud, O. Taalab, A. Rady, and H. A. Zoheir, "Transmuscular Quadratus Lumborum Block versus Suprainguinal Fascia Iliaca Block for Hip Arthroplasty: A Randomized, Controlled Pilot Study.", Local and regional anesthesia, vol. 14, pp. 67-74, 2021. Abstract

Background: This study aimed to investigate the analgesic efficacy and motor block profile of single-shot transmuscular quadratus lumborum block (QLB) in comparison with those of suprainguinal fascia iliaca block (FIB) in patients undergoing hip arthroplasty.

Methods: This randomized, double-blinded, controlled trial included adult patients undergoing hip arthroplasty under spinal anesthesia. Patients were allocated to one of two groups according to the regional block received: FIB group (n=19) or QLB group (n=17). Both study groups were compared with regard to the duration of analgesia (primary outcome), block performance time, pain during positioning for spinal anesthesia, total morphine consumption in the first postoperative 24-h period, quadriceps muscle power, and static and dynamic visual analog scale.

Results: Thirty-six patients were included in the final analysis. Both study groups had comparable durations of analgesia. Postoperative visual analog scale (static and dynamic) values were comparable between the two groups in most readings. The block performance time was shorter in the FIB group. The number of patients with pain during positioning for the subarachnoid block was lower in the QLB group. The total morphine requirement during the first 24 h was marginally lower in the FIB group, whereas the quadriceps motor grade was higher in the FIB group than in the QLB group at 4 h and 6 h after surgery.

Conclusion: Both single-shot blocks, namely the suprainguinal FIB and transmuscular QLB, provide effective postoperative analgesia after hip arthroplasty. FIB showed slightly lower 24-h morphine consumption, while QLB showed better quadriceps motor power.

Clinical Trial Registration: The study was registered at clinical trials registry system before enrollment of the first participant (NCT04005326; initial release date, 2 July 2019; https://clinicaltrials.gov/ct2/show/NCT04005326).

R
Refaat, S., M. Mostafa, A. Hasanin, N. Rujubali, R. Fouad, and Y. Hassabelnaby, "Accuracy of noninvasive blood pressure measured at the ankle during cesarean delivery under spinal anesthesia.", Journal of clinical monitoring and computing, vol. 35, issue 5, pp. 1211-1218, 2021. Abstract

In this study, we evaluated the accuracy of oscillometric noninvasive blood pressure (NIBP) measured at the ankle in detecting low arm NIBP during cesarean delivery under spinal anesthesia. In this prospective observational study, a cohort of full-term mothers undergoing elective cesarean delivery under spinal anesthesia was examined. Simultaneous NIBP measurements were obtained from the arm and the ankle. The primary outcome was the accuracy of the ankle NIBP in detecting arm systolic blood pressure (SBP) < 90 mmHg. Other outcomes included the accuracy of ankle NIBP in detecting SBP < 80% of the baseline value. The area under the receiver operating characteristic curve (AUC) was calculated to evaluate the accuracy of ankle NIBP in detecting low arm NIBP. The Bland-Altman analysis was conducted to evaluate the agreement between values. We analyzed 1729 pairs of readings obtained from 97 mothers. Ankle SBP showed good accuracy in detecting SBP < 90 mmHg, with an AUC (95% confidence interval [CI]) of 0.90 (0.89-0.91) and a negative predictive value (NPV) of 99 (98-99%) at a cutoff value of ≤ 103 mmHg. Furthermore, ankle SBP showed good accuracy in detecting SBP < 80% of the baseline value, with an AUC (95% CI) of 0.84 (0.82-0.89) and an NPV of 95 (93-96%) at a cutoff value of ≤ 76% of the ankle baseline SBP. The mean bias between the two sites of measurement was - 5.4 ± 15.5, - 2.0 ± 11, and 0.5 ± 12.1 mmHg for SBP, diastolic blood pressure, and mean arterial pressure, respectively. In conclusion, ankle NIBP measurement is not interchangeable with arm NIBP measurement. However, ankle NIBP measurement showed good accuracy for ruling out low arm NIBP during a cesarean delivery.Clinical trial rejistration: NCT04199156.

S
Sabry, R., A. Hasanin, S. Refaat, S. A. E. Raouf, A. S. Abdallah, and N. Helmy, "Evaluation of Gastric Residual Volume in Fasting Diabetic Patients Using Gastric Ultrasound", Acta Anaesthesiologica Scandinavica, vol. 63, issue 5, pp. 615-619, 2019.
Z
Zayed, M., H. Nassar, A. Hasanin, A. H. Saleh, P. Hassan, D. Saad, S. A. H. A. R. MAHMOUD, G. A. Bakr, E. fouad, N. Saleh, et al., "Effects of nitroglycerin versus labetalol on peripheral perfusion during deliberate hypotension for sinus endoscopic surgery: a randomized, controlled, double-blinded trial.", BMC anesthesiology, vol. 20, issue 1, pp. 85, 2020. Abstract

BACKGROUND: Deliberate hypotension is used to provide a bloodless field during functional endoscopic sinus surgery; however, the impact of controlled hypotension during anesthesia on peripheral tissue perfusion has not been extensively evaluated. The aim of this study was to compare the impact of nitroglycerin- versus labetalol-induced hypotension on peripheral perfusion.

METHODS: The present randomized, double-blinded, controlled trial included adult patients undergoing endoscopic sinus surgery. Patients were allocated to one of two groups according to the drug received for induction of deliberate hypotension: nitroglycerin (n = 20) or labetalol (n = 20). Mean arterial pressure was maintained at 55-65 mmHg in both groups. Both study groups were compared according to pulse oximeter-derived peripheral perfusion index (primary outcome), serum lactate level, mean arterial pressure, heart rate, surgical field score, and intraoperative blood loss.

RESULTS: Forty patients were included in the final analysis. The nitroglycerin group exhibited a higher peripheral perfusion index at nearly all records (p < 0.0001) and lower postoperative serum lactate levels (1.3 ± 0.2 mmol/L vs. 1.7 ± 0.4 mmol/L; p = 0.001) than the labetalol group. The peripheral perfusion index was higher in the nitroglycerin group than at baseline at most intraoperative readings. The median surgical field score was modestly lower in the labetalol group than in the nitroglycerin group in the first 20 min (2 [interquartile range (IQR) 2-2.5] versus 1.5 [IQR 1-2]; p = 0.001). Both groups demonstrated comparable and acceptable surgical field scores in all subsequent readings.

CONCLUSION: Nitroglycerin-induced deliberate hypotension was accompanied by higher peripheral perfusion index and lower serum lactate levels than labetalol-induced deliberate hypotension during sinus endoscopic surgery.

TRIAL REGISTRATION: The study was registered at clinicaltrials registry system with trial number: NCT03809065. Registered at 19 January 2019. This study adheres to CONSORT guidelines.